Separation of dichlorprop methyl enantiomers
Separation of dichlorprop methyl enantiomers
Separation of dichlorprop methyl enantiomers
- Application Number
- 106060
- Method
- HPLC
- Results
- Substances
- dichlorprop methyl
- Product(s)
Phase REF Webshop NUCLEOSIL CHIRAL-3
720350.40
NUCLEOSIL CHIRAL-2
720088.40
- Matrix
- Sample(s)
- Conditions
Injection volume: 1 µL Eluent: n-heptane - 2-propanol - trifluoroacetic acid (100:0.05:0.05, v/v/v) Flow rate: 1 mL/min Temperature: ambient
- Detection
- UV, 230 nm, sensitivity 0.08
- Note
- Both columns carry the same chiral selector. They differ only in the configuration of the chiral center of the selector. The selectivity towards a racemic mixture as well as the chromatographic resolution are exactly the same. However, the elution sequence of the enantiomers is reversed.
- Author
- LC department
- Source
- MACHEREY-NAGEL
- Disclaimer
- Concerning questions to literature applications please contact the cited author/s. Chemicals mentioned in applications are not manufactured or sold by MACHEREY-NAGEL. Applications mentioned in MACHEREY-NAGEL literature or databases are provided for informational purposes only. MACHEREY-NAGEL does not warrant that all applications have been tested in MACHEREY-NAGEL laboratories using MACHEREY-NAGEL products. MACHEREY-NAGEL does not warrant the correctness of the applications.